Siemens SINUMERIK Integrate and SINUMERIK Operate
A certificate validation weakness (CWE-300) in Siemens SINUMERIK Integrate and SINUMERIK Operate allows remote exploitation. The vulnerability affects SINUMERIK Integrate Operate Client versions 3.0.4 through 3.0.6 and 2.0.3 through 2.0.6, and Operate releases 4.5 SP6 through 4.5 SP6 Hotfix 8 and 4.7 SP2 Hotfix 1 through 4.7 SP4. An unauthenticated attacker on the network can intercept communications between the client and machine control system by presenting a fraudulent certificate, potentially allowing unauthorized machine control or data manipulation. Siemens states no patch is planned for affected versions.
- Network access between SINUMERIK client and machine control system (can be local network or remote if client exposed to internet)
- Client or Operate software running with vulnerable versions installed
- No mutual certificate pinning or strict certificate validation in use
Patching may require device reboot — plan for process interruption