OTPulse

Geutebrück GmbH E2 Series IP Cameras

Plan Patch7.2ICS-CERT ICSA-18-347-03Dec 13, 2018
Attack VectorNetwork
Auth RequiredHigh
ComplexityLow
User InteractionNone needed
Summary

Geutebrück E2 series IP cameras contain an OS command injection vulnerability that allows a remote attacker with administrative credentials to inject and execute arbitrary OS commands with root privileges. The vulnerability affects firmware versions prior to 1.12.0.25. Successful exploitation could allow an attacker to modify camera settings, disable surveillance, access recorded footage, or pivot into the facility network.

What this means
What could happen
An attacker with administrative access to a Geutebrück E2 camera could run arbitrary commands as root, potentially altering camera configuration, disabling surveillance, or using the device as a pivot point into your network.
Who's at risk
Any organization using Geutebrück E2 series IP cameras for surveillance in industrial facilities, water/electric utilities, or critical infrastructure. This includes security monitoring in control rooms, perimeter surveillance, and facility monitoring systems.
How it could be exploited
An attacker must authenticate to the camera's web interface using valid administrative credentials, then inject OS commands through an input field (likely in configuration or settings). The commands execute with root privileges on the camera.
Prerequisites
  • Valid administrative (root-level) credentials for the camera
  • Network access to the camera's web management interface (typically port 80/443)
  • Camera running firmware version 1.12.0.25 or earlier
Remotely exploitable via web interfaceRequires valid credentials (mitigating factor)Command injection leads to root accessLow public awareness (CISA advisory from 2018)Affects physical security infrastructure
Exploitability
Moderate exploit probability (EPSS 1.5%)
Affected products (1)
ProductAffected VersionsFix Status
E2 Camera Series - Geutebrück reports the vulnerability affect the following IP cameras:E2 series cameras running firmware<1.12.0.251.12.0.25
Remediation & Mitigation
0/5
Do now
0/3
WORKAROUNDRestrict network access to camera management interfaces: place cameras behind firewall with rules limiting access to authorized maintenance personnel only
HARDENINGRemove cameras from direct Internet exposure; ensure they are only reachable from your internal network
HARDENINGChange default and shared administrative passwords on all E2 cameras to unique, strong credentials
Schedule — requires maintenance window
0/1

Patching may require device reboot — plan for process interruption

HOTFIXUpdate all E2 series cameras to firmware version 1.12.0.25 or later by downloading from Geutebrück WebClub portal
Long-term hardening
0/1
HARDENINGSegment camera network from business network and critical control systems using separate VLANs or firewalls
↑↓ Navigate · Esc Close
API: /api/v1/advisories/64e5f98d-145c-4815-8b0b-024f41398a1b