OTPulse

Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1

Act Now9.6SSA-381581Jul 9, 2024
Attack VectorNetwork
Auth RequiredLow
ComplexityLow
User InteractionNone needed
Summary

SINEMA Remote Connect Server versions prior to V3.2 SP1 contain multiple vulnerabilities across authentication, file handling, privilege escalation, and access control mechanisms (CWE-286, CWE-434, CWE-267, CWE-425, CWE-754, CWE-602, CWE-863, CWE-378, CWE-307, CWE-732, CWE-770). A user with valid credentials could exploit these to gain elevated privileges, upload malicious files, or escalate access within the server environment.

What this means
What could happen
An attacker with valid credentials could exploit multiple vulnerabilities in SINEMA Remote Connect Server to remotely execute code or gain unauthorized access to remote engineering workstations and industrial control devices connected through the VPN tunnel, potentially allowing them to alter device configurations or disrupt remote operations.
Who's at risk
Organizations using Siemens SINEMA Remote Connect Server for secure remote access to industrial control systems, engineering workstations, and critical infrastructure. This includes water utilities, power generation and distribution facilities, manufacturing plants, and any organization managing remote access to PLCs, RTUs, HMIs, or engineering networks via this VPN gateway.
How it could be exploited
An attacker with valid login credentials accesses SINEMA Remote Connect Server over the network. They exploit one or more of the authentication, file upload, or privilege escalation vulnerabilities to gain elevated access on the server. From there, they could establish a VPN tunnel to reach protected industrial devices or engineering workstations behind the server, or execute commands on the server itself to modify configurations or intercept credentials.
Prerequisites
  • Valid login credentials for SINEMA Remote Connect Server
  • Network access to the server's management interface (typically port 443 or similar)
  • SINEMA version prior to V3.2 SP1
Remotely exploitableRequires valid credentials (moderate barrier)Low complexity attackEPSS score above 10% (10.5%)Affects remote access to ICS/OT devicesMultiple vulnerability classes present
Exploitability
High exploit probability (EPSS 10.5%)
Affected products (1)
ProductAffected VersionsFix Status
SINEMA Remote Connect ServerAll versions < V3.2 SP13.2 SP1
Remediation & Mitigation
0/1
Schedule — requires maintenance window
0/1

Patching may require device reboot — plan for process interruption

HOTFIXUpdate SINEMA Remote Connect Server to version V3.2 SP1 or later
↑↓ Navigate · Esc Close
API: /api/v1/advisories/e2e5fd4b-60f9-4bb7-ae45-2a295c5c96a8